Rabu, 23 April 2014

NetApp Configuration FAS3250


Version :
FAS3250-ctrl1> version
NetApp Release 8.1.3 7-Mode: Sat Jun  8 08:11:51 PDT 2013

Check Aggregat :
FAS3250-ctrl1> aggr status
           Aggr State           Status            Options
          aggr0 online          raid_dp, aggr     root
                                64-bit 

Check Volume :
FAS3250-ctrl1> vol status
         Volume State           Status            Options
           vol0 online          raid_dp, flex     root, create_ucode=on
                                64-bit

Check HA Status :
FAS3250-ctrl1> cf status
Controller Failover disabled.
RDMA Interconnect is up (Link 0 up, Link 1 up).

Check Disk Status :
FAS3250-ctrl1> disk show
  DISK       OWNER                      POOL   SERIAL NUMBER         HOME 
------------ -------------              -----  -------------         ------------- 
0a.00.5      FAS3250-ctrl1(2017399330)    Pool0  KNX8ZX2R              FAS3250-ctrl1(2017399330)
0a.00.8      FAS3250-ctrl1(2017399330)    Pool0  KNXA7XLR              FAS3250-ctrl1(2017399330)
..
..

Check Disk Not Owned Status :
FAS3250-ctrl1> disk show -n
  DISK       OWNER                      POOL   SERIAL NUMBER         HOME 
------------ -------------              -----  -------------         ------------- 
4d.11.2      Not Owned                  NONE   93J0A0IRFUZ6       
4d.11.3      Not Owned                  NONE   93J0A0PSFUZ6       
4d.11.22     Not Owned                  NONE   93J0A0IAFUZ6 
..
..


Capture System Configuration :
FAS3250-ctrl1> sysconfig -a
 NetApp Release 8.1.3 7-Mode: Sat Jun  8 08:11:51 PDT 2013
 System ID: 2017399330 (FAS3250-ctrl1); partner ID: 2017292074 (JSG22-filer)
 System Serial Number: 450000025964 (FAS3250-ctrl1)
 System Rev: B7
 System Storage Configuration: Multi-Path HA
 System ACP Connectivity: Full Connectivity
 slot 0: System Board 2.3 GHz (System Board XVI B7)
                Model Name:         FAS3250
                Part Number:        111-01062
..
..

Create Volume :
FAS3250-ctrl1> vol create vol_570T aggr_1 400g

Create LUN :
FAS3250-ctrl1> lun create -s 120g -t windows -o noreserve /vol/vol_1T4P1/L_Fin_Ap1
lun create: created a LUN of size:  120.0g (128857236480)
FAS3250-ctrl1> lun create -s 120g -t windows -o noreserve /vol/vol_1T4P1/L_Fin_DB1
lun create: created a LUN of size:  120.0g (128857236480)

View LUN :
FAS3250-ctrl1> lun show
 /vol/vol_1T4P1/L_DNS1       60.0g (64436843520)   (r/w, online)
 /vol/vol_1T4P1/L_EB_Ap1    120.0g (128857236480)  (r/w, online)

View Mapped LUN :
FAS3250-ctrl1> lun show -m
 /vol/vol_1T4P1/L_DNS1       60.0g (64436843520)   (r/w, online)
 /vol/vol_1T4P1/L_EB_Ap1    120.0g (128857236480)  (r/w, online)


Show FCP Port :
FAS3250-ctrl1> fcp config
2a:   OFFLINED BY USER/SYSTEM <ADAPTER DOWN> 
        host address 000000
        portname 50:0a:09:81:88:8d:6f:2a  nodename 50:0a:09:80:88:8d:6f:2a
        mediatype auto speed auto
2b:   OFFLINED BY USER/SYSTEM <ADAPTER DOWN> 
        host address 000000
        portname 50:0a:09:82:88:8d:6f:2a  nodename 50:0a:09:80:88:8d:6f:2a
        mediatype auto speed auto


FCP Port Type :
FAS3250-ctrl1> fcadmin config
                  Local  
Adapter Type      State                  Status
---------------------------------------------------
  0c   initiator  CONFIGURED.            offline
  0d   initiator  CONFIGURED.            offline
Change Port Type :
FAS3250-ctrl1> fcadmin config -d 0c
FAS3250-ctrl1> fcadmin config -t target 0d
A reboot is required for the new adapter configuration to take effect.
<need reboot>

FAS3250-ctrl1>fcadmin config
                  Local  
Adapter Type      State                  Status
---------------------------------------------------
  0c   target     CONFIGURED             offline
  0d   target     CONFIGURED             offline

FAS3250-ctrl1> fcp start
FAS3250-ctrl1>fcadmin config
                  Local  
Adapter Type      State                  Status
---------------------------------------------------
  0c   target     CONFIGURED             online
  0d   target     CONFIGURED             online



FAS3250-ctrl1> lun config_check
The following FCP HBAs appear to be down
    2a  LINK NOT CONNECTED
    0c  LINK NOT CONNECTED
    0d  LINK NOT CONNECTED