Setelah config dengan serial, bias telnet lewat IP sbb :
=~=~=~=~=~=~=~=~=~=~=~= PuTTY log 2013.11.26 09:42:10 =~=~=~=~=~=~=~=~=~=~=~=
sntstorage> qtree
qtree: This command is deprecated; using qtree status.
Volume Tree Style Oplocks Status
-------- -------- ----- -------- ---------
vol0 unix enabled normal
vol_mbx_bod unix enabled normal
vol_mbx_bod q_mbx_bod unix enabled normal
vol_mbx_common unix enabled normal
vol_mbx_common q_mbx_common unix enabled normal
vol_log unix enabled normal
vol_log q_log unix enabled normal
vol_journal unix enabled normal
vol_journal q_journal unix enabled normal
sntstorage> lun create -s 1t -t windows /vol/vol_mbx_bod/q_mbx_bod/mbxbod
lun create: created a LUN of size: 1.0t (1099604782080)
sntstorage> lun create -s 1t -t windows /vol/vol_mbx_common/q_mbx_common/mbxcommon
lun create: created a LUN of size: 1.0t (1099604782080)
sntstorage> lun create -s 250g -t windows /vol/vol_journal/q_journal/journal
lun create: created a LUN of size: 250.0g (268473139200)
sntstorage> lun create -s 250g -t windows /vol/vol_log/q_log/log
lun create: created a LUN of size: 250.0g (268473139200)
sntstorage> lun show
/vol/vol_journal/q_journal/journal 250.0g (268473139200) (r/w, online)
/vol/vol_log/q_log/log 250.0g (268473139200) (r/w, online)
/vol/vol_mbx_bod/q_mbx_bod/mbxbod 1.0t (1099604782080) (r/w, online)
/vol/vol_mbx_common/q_mbx_common/mbxcommon 1.0t (1099604782080) (r/w, online)
sntstorage> qtree
qtree: This command is deprecated; using qtree status.
Volume Tree Style Oplocks Status
-------- -------- ----- -------- ---------
vol0 unix enabled normal
vol_mbx_bod unix enabled normal
vol_mbx_bod q_mbx_bod unix enabled normal
vol_mbx_common unix enabled normal
vol_mbx_common q_mbx_common unix enabled normal
vol_log unix enabled normal
vol_log q_log unix enabled normal
vol_journal unix enabled normal
vol_journal q_journal unix enabled normal
sntstorage> vol status
Volume State Status Options
vol0 online raid_dp, flex root
64-bit
vol_mbx_bod online raid_dp, flex nosnap=on, create_ucode=on, convert_ucode=on,
64-bit no_i2p=on, fractional_reserve=0
vol_mbx_common online raid_dp, flex nosnap=on, create_ucode=on, convert_ucode=on,
64-bit no_i2p=on, fractional_reserve=0
vol_log online raid_dp, flex nosnap=on, create_ucode=on, convert_ucode=on,
64-bit no_i2p=on, fractional_reserve=0
vol_journal online raid_dp, flex nosnap=on, create_ucode=on, convert_ucode=on,
64-bit no_i2p=on, fractional_reserve=0
sntstorage> aggr status
Aggr State Status Options
aggr0 online raid_dp, aggr root
64-bit
aggr1 online raid_dp, aggr nosnap=on
64-bit
sntstorage> cf enable
cf: clustering already enabled
sntstorage> fcp start
fcp: No FCP Target Adapters are present in this system.
sntstorage> fcadmin config
Local
Adapter Type State Status
---------------------------------------------------
1a initiator CONFIGURED. online
1b initiator CONFIGURED. offline
sntstorage> fcadmin config -t target 1a
A reboot is required for the new adapter configuration to take effect.
sntstorage> fcadmin config -t target 1b
A reboot is required for the new adapter configuration to take effect.
sntstorage> reboot
sntstorage> fcadmin config
Local
Adapter Type State Status
---------------------------------------------------
1a target CONFIGURED offline
1b target CONFIGURED offline
sntstorage> fcp start
sntstorage> fcadmin config
Local
Adapter Type State Status
---------------------------------------------------
1a target CONFIGURED online
1b target CONFIGURED online
sntstorage> sysconfig -r
Aggregate aggr0 (online, raid_dp) (block checksums)
Plex /aggr0/plex0 (online, normal, active, pool0)
RAID group /aggr0/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.00.0 0a 0 0 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
parity 0a.00.2 0a 0 2 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.4 0a 0 4 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
Aggregate aggr1 (online, raid_dp) (block checksums)
Plex /aggr1/plex0 (online, normal, active, pool0)
RAID group /aggr1/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.00.22 0a 0 22 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
parity 0a.00.18 0a 0 18 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.20 0a 0 20 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.6 0a 0 6 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.14 0a 0 14 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.16 0a 0 16 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.10 0a 0 10 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.12 0a 0 12 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
Pool1 spare disks (empty)
Pool0 spare disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
Spare disks for block checksum
spare 0a.00.8 0a 0 8 SA:A 0 SAS 10000 560000/1146880000 572325/1172123568
Partner disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
partner 0a.00.15 0a 0 15 SA:A 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.23 0a 0 23 SA:A 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.21 0a 0 21 SA:A 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.19 0a 0 19 SA:A 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.17 0a 0 17 SA:A 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.13 0a 0 13 SA:A 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.11 0a 0 11 SA:A 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.9 0a 0 9 SA:A 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.7 0a 0 7 SA:A 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.5 0a 0 5 SA:A 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.3 0a 0 3 SA:A 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.1 0a 0 1 SA:A 0 SAS 10000 0/0 572325/1172123568
=~=~=~=~=~=~=~=~=~=~=~= PuTTY log 2013.11.26 09:51:00 =~=~=~=~=~=~=~=~=~=~=~=
login as: root
root@172.16.32.59's password:
sntstorage2> qtree create /vol/vol_mbx_bod/q_mbx_bod
sntstorage2> qtree create /vol/vol_mbx_common/q_mbx_common
sntstorage2> qtree create /vol/vol_log/q_log
sntstorage2> qtree create /vol/vol_journal/q_journal
sntstorage2> qtree
qtree: This command is deprecated; using qtree status.
Volume Tree Style Oplocks Status
-------- -------- ----- -------- ---------
vol0 unix enabled normal
vol_mbx_bod unix enabled normal
vol_mbx_bod q_mbx_bod unix enabled normal
vol_mbx_common unix enabled normal
vol_mbx_common q_mbx_common unix enabled normal
vol_log unix enabled normal
vol_log q_log unix enabled normal
vol_journal unix enabled normal
vol_journal q_journal unix enabled normal
sntstorage2> lun create -s 1t -t windows /vol/vol_mbx_common/q_common/mbxcommon
lun create: created a LUN of size: 1.0t (1099604782080)
sntstorage2> lun create -s 250g -t windows /vol/vol_log/q_log/log
lun create: created a LUN of size: 250.0g (268473139200)
sntstorage2> lun create -s 250g -t windows /vol/vol_journal/q_journal/journal
lun create: created a LUN of size: 250.0g (268473139200)
sntstorage2> sysconfig -r
Aggregate aggr1 (online, raid_dp) (block checksums)
Plex /aggr1/plex0 (online, normal, active, pool0)
RAID group /aggr1/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.00.9 0a 0 9 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
parity 0a.00.17 0a 0 17 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.23 0a 0 23 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.11 0a 0 11 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.13 0a 0 13 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.15 0a 0 15 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.7 0a 0 7 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.21 0a 0 21 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
Aggregate aggr0 (online, raid_dp) (block checksums)
Plex /aggr0/plex0 (online, normal, active, pool0)
RAID group /aggr0/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.00.1 0a 0 1 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
parity 0a.00.3 0a 0 3 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
data 0a.00.5 0a 0 5 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
Pool1 spare disks (empty)
Pool0 spare disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
Spare disks for block checksum
spare 0a.00.19 0a 0 19 SA:B 0 SAS 10000 560000/1146880000 572325/1172123568
Partner disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
partner 0a.00.2 0a 0 2 SA:B 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.0 0a 0 0 SA:B 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.10 0a 0 10 SA:B 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.12 0a 0 12 SA:B 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.14 0a 0 14 SA:B 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.22 0a 0 22 SA:B 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.16 0a 0 16 SA:B 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.4 0a 0 4 SA:B 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.6 0a 0 6 SA:B 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.20 0a 0 20 SA:B 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.18 0a 0 18 SA:B 0 SAS 10000 0/0 572325/1172123568
partner 0a.00.8 0a 0 8 SA:B 0 SAS 10000 0/0 572325/1172123568
sntstorage2> sysconfig -a
NetApp Release 8.1.2 7-Mode: Tue Oct 30 19:56:51 PDT 2012
System ID: 1234567890 (XXXXXXX); partner ID: 10987654321 (YYYYYYY)
System Serial Number: 940000496899 (sntstorage2)
System Rev: D1
System Storage Configuration: Single-Path HA
System ACP Connectivity: Partial Connectivity
slot 0: System Board 1.7 GHz (System Board XIX D1)
Model Name: FAS2240-2
Part Number: 111-00846
Revision: D1
Serial Number: *********
BIOS version: 8.1.0
Loader version: 4.1
Processors: 4
Processor ID: 0x106e4
Microcode Version: 0xffff0002
Processor type: Intel(R) Xeon(R) CPU C3528 @ 1.73GHz
Memory Size: 6144 MB
Memory Attributes: Hoisting
Normal ECC
NVMEM Size: 768 MB of Main Memory Used
CMOS RAM Status: OK
Controller: B
Service Processor Status: Online
Firmware Version: 2.1.2
Mgmt MAC Address: 00:A0:98:3F:F7:7A
Ethernet Link: up, 100Mb, full duplex, auto-neg complete
Using DHCP: no
IPv4 configuration:
IP Address: 192.168.1.115
Netmask: 255.255.255.0
Gateway: 192.168.1.1
IPv6 configuration: Disabled
slot 0: Internal 10/100 Ethernet Controller
e0M MAC Address: 00:a0:98:3f:f7:79 (auto-100tx-fd-up)
e0P MAC Address: 00:a0:98:3f:f7:78 (auto-100tx-fd-up)
Device Type: Rev 0
memory mapped I/O base 0x00000000dfa00000, size 0x20000
I/O base 0x0000000000003000, size 0x20
memory mapped I/O base 0x00000000dfa20000, size 0x4000
memory mapped I/O base 0x00000000dfb20000, size 0x20000
I/O base 0x0000000000004000, size 0x20
memory mapped I/O base 0x00000000dfb00000, size 0x4000
slot 0: Quad Gigabit Ethernet Controller 82580
e0a MAC Address: 00:a0:98:3f:f7:74 (auto-unknown-down)
e0b MAC Address: 00:a0:98:3f:f7:75 (auto-unknown-down)
e0c MAC Address: 00:a0:98:3f:f7:76 (auto-unknown-down)
e0d MAC Address: 00:a0:98:3f:f7:77 (auto-unknown-down)
Device Type: 150E
memory mapped I/O base 0x00000000df700000, size 0x80000
I/O base 0x0000000000002040, size 0x20
memory mapped I/O base 0x00000000df808000, size 0x4000
memory mapped I/O base 0x00000000df780000, size 0x80000
I/O base 0x0000000000002060, size 0x20
memory mapped I/O base 0x00000000df80c000, size 0x4000
memory mapped I/O base 0x00000000df600000, size 0x80000
I/O base 0x0000000000002000, size 0x20
memory mapped I/O base 0x00000000df800000, size 0x4000
memory mapped I/O base 0x00000000df680000, size 0x80000
I/O base 0x0000000000002020, size 0x20
memory mapped I/O base 0x00000000df804000, size 0x4000
slot 0: Interconnect HBA: Mellanox IB MT25204
GUID: 0x100000a0983ff774 LID: 0x5 Remote LID: 0x4
Firmware rev: 1.0.800
Hardware rev: 160
Command rev: 1
Cluster Interconnect Port: 4x
memory mapped I/O base 0xdf400000, size 0x100000
prefetchable memory base 0xde800000, size 0x800000
slot 0: SAS Host Adapter 0a (PMC-Sierra PM8001 rev. C, SAS, <UP>)
Firmware rev: 01.11.00.00
Base WWN: 5:00a098:0018d42:70
Phy State: [0] Enabled, 6.0 Gb/s
[1] Enabled, 6.0 Gb/s
[2] Enabled, 6.0 Gb/s
[3] Enabled, 6.0 Gb/s
00.0 : NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNH9VLAF)
00.1 : NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHKTL1F)
00.2 : NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHMU1RF)
00.3 : NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHL820F)
00.4 : NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNVYRMMF)
00.5 : NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNH2SH4F)
00.6 : NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNVZ2APF)
00.7 : NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNVUYXPF)
00.8 : NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNH3EYKF)
00.9 : NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNH9T51F)
00.10: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNVZ28XF)
00.11: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHA9TKF)
00.12: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHMWKDF)
00.13: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHJ23HF)
00.14: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHMUTPF)
00.15: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHMUPRF)
00.16: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNH9T08F)
00.17: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNH9T0RF)
00.18: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNVZ365F)
00.19: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHLL6TF)
00.20: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHA9K8F)
00.21: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHMSP1F)
00.22: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHL7TUF)
00.23: NETAPP X422_HCOBE600A10 NA00 560.0GB 520B/sect (KNHAAMZF)
Shelf 0: IOM6E Firmware rev. IOM6E A: 0121 IOM6E B: 0121
slot 0: SAS Host Adapter 0b (PMC-Sierra PM8001 rev. C, SAS, <OFFLINE (hard)>)
Firmware rev: 01.11.00.00
Base WWN: 5:00a098:0018d42:74
Phy State: [4] Disabled
[5] Disabled
[6] Disabled
[7] Disabled
QSFP Vendor: not available
QSFP Part Number: not available
QSFP Type: not available
QSFP Serial Number: not available
memory mapped I/O base 0xdf530000, size 0x10000
memory mapped I/O base 0xdf520000, size 0x10000
memory mapped I/O base 0x00000000df510000, size 0x10000
memory mapped I/O base 0x00000000df500000, size 0x10000
slot 0: Intel ICH USB EHCI Adapter u0a (0xdf101000)
boot0 Micron Technology Real SSD eUSB 2GB, class 0/0, rev 2.00/11.10, addr 2 1936MB 512B/sect (B9F0022700106385)
memory-mapped I/O base 0xdf101000, size 0x400
slot 1: FC Host Adapter 1a (QLogic 2532 rev. 2, N-port, <UP>)
Board name: 111-00811+A2
Serial Number: **********
Firmware rev: 5.4.130
Host Port Id: 0x11000
FC Node Name: 5:00a:098001:b24225
FC Port Name: 5:00a:098001:b24225
SFP Vendor: FINISAR CORP.
SFP Part Number: FTLF8528P2BNV
SFP Serial Number: PNN4G49
SFP Capabilities: 2, 4 or 8 Gbit
Link Data Rate: 4 Gbit
Switch Port: QLOGIC4Gb:16
I/O base 0x00000000ffffff00, size 0x100
memory mapped I/O base 0xdf900000, size 0x4000
slot 1: FC Host Adapter 1b (QLogic 2532 rev. 2, L-port, <OFFLINE (hard)>)
Board name: 111-00811+A2
Serial Number: **********
Firmware rev: 5.4.130
Host Loop Id: 0
FC Node Name: 5:00a:098101:b24225
FC Port Name: 5:00a:098101:b24225
SFP Vendor: FINISAR CORP.
SFP Part Number: FTLF8528P2BNV
SFP Serial Number: PNN4GGL
SFP Capabilities: 2, 4 or 8 Gbit
Link Data Rate: N/A
I/O base 0x00000000ffffff00, size 0x100
memory mapped I/O base 0xdf904000, size 0x4000
sntstorage2> cf enable
cf: clustering already enabled
sntstorage2> storage show adapter
Slot: 0a
Description: SAS Host Adapter 0a (PMC-Sierra PM8001 rev. C)
Firmware Rev: 01.11.00.00
Base WWN: 5:00a098:0018d42:70
State: Enabled
In Use: Yes
Redundant: No
Phy State: [0] Enabled, 6.0Gb/s (10)
[1] Enabled, 6.0Gb/s (10)
[2] Enabled, 6.0Gb/s (10)
[3] Enabled, 6.0Gb/s (10)
Slot: 0b
Description: SAS Host Adapter 0b (PMC-Sierra PM8001 rev. C)
Firmware Rev: 01.11.00.00
Base WWN: 5:00a098:0018d42:74
State: Disabled
In Use: No
Redundant: Yes
Phy State: [0] Disabled (1)
[1] Disabled (1)
[2] Disabled (1)
[3] Disabled (1)
Slot: 1a
Description: Fibre Channel Host Adapter 1a (QLogic 2532 rev. 2)
Firmware Rev: 5.4.130
FC Node Name: 5:00a:098001:b24225
FC Port Name: 5:00a:098001:b24225
FC Packet Size: 2048
Link Data Rate: 4 Gbit
SRAM Parity: Yes
External GBIC: No
State: Enabled
In Use: No
Redundant: Yes
Slot: 1b
Description: Fibre Channel Host Adapter 1b (QLogic 2532 rev. 2)
Firmware Rev: 5.4.130
FC Node Name: 5:00a:098101:b24225
FC Port Name: 5:00a:098101:b24225
FC Packet Size: 2048
Link Data Rate: N/A
SRAM Parity: Yes
External GBIC: No
State: Disabled
In Use: No
Redundant: Yes
sntstorage2> fcadmin config
Local
Adapter Type State Status
---------------------------------------------------
1a initiator CONFIGURED. online
1b initiator CONFIGURED. offline
sntstorage2> fcadmin config -d 1a
sntstorage2> fcadmin config -t target 1a
A reboot is required for the new adapter configuration to take effect.
sntstorage2> fcadmin config -d 1b
sntstorage2> fcadmin config -t target 1b
A reboot is required for the new adapter configuration to take effect.
sntstorage2> fcadmin config
Local
Adapter Type State Status
---------------------------------------------------
1a initiator PENDING (target) offline
1b initiator PENDING (target) offline
sntstorage2> reboot
sntstorage2> fcadmin config
Local
Adapter Type State Status
---------------------------------------------------
1a target CONFIGURED offline
1b target CONFIGURED offline
sntstorage2> fcp status
FCP service is not running.
sntstorage2> fcp start
sntstorage2> fcadmin config
Local
Adapter Type State Status
---------------------------------------------------
1a target CONFIGURED online
1b target CONFIGURED online
=~=~=~=~=~=~=~=~=~=~=~= PuTTY log 2013.11.26 14:16:44 =~=~=~=~=~=~=~=~=~=~=~=
igroup show -v
sntstorage2> fcp show adapter
Slot: 1a
Description: Fibre Channel Target Adapter 1a (QLogic 2532 (2562) rev. 2)
Adapter Type: Local
Status: ONLINE
FC Nodename: 50:0a:09:80:81:b6:ae:de (500a098081b6aede)
FC Portname: 50:0a:09:81:91:b6:ae:de (500a098191b6aede)
Standby: No
Slot: 1b
Description: Fibre Channel Target Adapter 1b (QLogic 2532 (2562) rev. 2)
Adapter Type: Local
Status: ONLINE
FC Nodename: 50:0a:09:80:81:b6:ae:de (500a098081b6aede)
FC Portname: 50:0a:09:82:91:b6:ae:de (500a098291b6aede)
Standby: No
sntstorage2> fcpshow initiators
Initiators connected on adapter 1a:
Portname Group
-------- -----
21:00:00:24:ff:4a:a5:e7
Initiators connected on adapter 1b:
Portname Group
-------- -----
21:00:00:24:ff:4a:a5:fe
21:00:00:24:ff:4a:a5:e6
sntstorage2> fcp show initiators
Initiators connected on adapter 1a:
Portname Group
-------- -----
21:00:00:24:ff:4a:a5:e7
Initiators connected on adapter 1b:
Portname Group
-------- -----
21:00:00:24:ff:4a:a5:fe
21:00:00:24:ff:4a:a5:e6
sntstorage2> igroup create -f -t windows mbx1_hosts 210024ff4aa5e6 21000024ff4aa5e7
sntstorage2> igroup show
mbx1_hosts (FCP) (ostype: windows):
21:00:00:24:ff:4a:a5:e6 (logged in on: 1b)
21:00:00:24:ff:4a:a5:e7 (logged in on: 1a)
sntstorage2> lun show
/vol/vol_journal/q_journal/journal 250.0g (268473139200) (r/w, online)
/vol/vol_log/q_log/log 250.0g (268473139200) (r/w, online)
/vol/vol_mbx_bod/q_mbx_bod/mbxbod 1.0t (1099604782080) (r/w, online)
/vol/vol_mbx_common/q_mbx_common/mbxcommon 1.0t (1099604782080) (r/w, online)
sntstorage2> lun map /vol/vol_journal/q_journal/journal mbx1_hosts 0
sntstorage2> lun map /vol/vol_log/q_log/log mbx1_hosts 1
sntstorage2> lun map /vol/vol_mbx_bod/q_mbx_bod/mbxbod mbx1_hosts 2
sntstorage2> lun map /vol/vol_mbx_common/q_mbx_common/mbxcommon mbx1_hosts 3
sntstorage2> fcp show initiators
Initiators connected on adapter 1a:
Portname Group
-------- -----
21:00:00:24:ff:4a:a5:e7 mbx1_hosts
Initiators connected on adapter 1b:
Portname Group
-------- -----
21:00:00:24:ff:4a:a5:e6 mbx1_hosts
21:00:00:24:ff:4a:a5:fe
sntstorage2> igroup show
mbx1_hosts (FCP) (ostype: windows):
21:00:00:24:ff:4a:a5:e6 (logged in on: 1b)
21:00:00:24:ff:4a:a5:e7 (logged in on: 1a)
Tidak ada komentar: